Compatible blocking cables

  • YSQC0-002-0000 Cable Xerox (FDI Required)

  • YSQC0-003-0000 Cable Xerox Type 2 (FDI Required)

  • YSQC0-019-0000 Cable Xerox Type 3 (FDI Required)

  • YSQC0-048-0000 Smart Cable Xerox v2 (FDI Required - Recommended for Fuji Xerox MFP)

Blocking FujiXerox device

The device will be blocked after connecting the FDI with switches configured to 1111101000

  1. Enter service mode.
  2. Configure each Key chain value to Enable.
  3. After entering each value, touch Exit (keep log) > YES.

Each partner shall obtain pass code to enter service mode as well as Key Chain values from Fuji Xerox. YSoft cannot disclose this information which is covered by NDA.

 

Description

NVN Parameter

NVN Value

A

NVN for EPA accessory - enable

Ask Fuji Xerox

Ask Fuji Xerox

B

NVM for BARE - enable (For blocking with YSoft Terminal Professional/Ultralight)

Ask Fuji Xerox

Ask Fuji Xerox

C

NVM for FX IC CARD GATE - enable (For YSoft SafeQ Terminal Embedded)

Ask Fuji Xerox

Ask Fuji Xerox

D

NVN for Copy/print control - enable

Ask Fuji Xerox

Ask Fuji Xerox

E

NVN for FAX/Scan control - enable

Ask Fuji Xerox

Ask Fuji Xerox

To unblock the device it is necessary to disable NVN B or C and A before unplug Bare FDI / EPA Card reader.

How to choose a correct blocking cable mode on YSQC0-048-0000

On devices supporting blocking cable YSQC0-048-0000 requires selecting a correct blocking cable mode (mode can be found in HCL on Partner Portal). Here is the procedure:

Terminal Professional:

  1. In the service menu of terminal proceed following way: I/O Module settings -> I/O module
  2. Select YSQC0-048-0000 Smart Cable Xerox v2 is chosen and on the next screen set it to be operating in mode corresponding with the device used.

Terminal Ultralight:

  1. Use the termtool utility, how to use guide can be found in Configuring Terminal UltraLight article.
  2. After selecting the proper terminal to configure continue with entering 4 – Car reader and IO module setup and confirm with Enter. Press Enter one more time to skip the card reader setting. 
  3. By entering '?' You can list all the available types. Choose YSQC0-048-0000 Smart Cable Xerox v2.
  4. Choose mode corresponding with the used device. confirm by pressing Enter.
  5. Press Enter one more time and continue entering 100 in order to reboot the terminal and save changes made in its configuration.

Examples of blocking cable connection:

Xerox WorkCenter 7120

YSQC0-048-0000 Smart Cable Xerox v2 (FDI Required)

Smart Blocking Cables for Hardware Terminals

Requires Bear Solutions EPSV kit and Smart blocking cable


YSQC0-048-0000